(Store this Quick Reference Guide with the Owner’s Manual for future use)
Programming Functions
Set the dip switches according to this Quick Reference Guide
and, with the engine off and ignition on to the RUN position,
plug the module into the OBD port. The RUN position is two
“clicks” in with the key, all the lights on the cluster should
be on in RUN mode. The horn will sound twice when the
programming has been successfully completed. After the
horn sounds, remove the Procal and cycle the ignition off
and then on again.
Runtime Functions
Set the dip switches according to this Quick Reference
Guide and with the conditions in the user guide met, plug
the module into the OBD port. Some functions will require
special conditions like the e-brake to be set and/or the
engine running before plugging the Procal in for example.
User Guide
Please consult the User Guide for detailed information
regarding each mode and troubleshooting.
Online documentation
Digital versions of this Quick Reference Guide and the
Procal Module User Guide are available online at:
www.aev-conversions.com/education/installation-guides
INSTRUCTIONS TIRE SIZES 24”38” TIRE SIZES 39”54” LOW TIRE PRESSURE THRESHOLD
1 1 1
2 2 2
3 3
4
4
Set the rst 3 DIP switches as shown. Set the rst 3 DIP switches as shown. Set the rst 3 DIP switches as shown.
Use the chart below to set the next 6 for your
preferred tire pressure threshold.
* Setting the TPMS to a disabled value is for
diagnostic purposes only, see User Guide for details.
This option may be restricted in some areas.
Enter your exact tire
measurement to the
closest .25 inch
Enter your exact tire
measurement to the
closest .25 inch
A AB B
34.75” Tire Example: A = 34 b = .75 44.75” Tire Example: A = 44 b = .75
Using the A value from step 2, use the chart below
to set the next 4.
Using the A value from step 2, use the chart below
to set the next 4.
Using the B value from step 2, use the chart below
to set the last 2.
Using the B value from step 2, use the chart below
to set the last 2.
DISABLING TpmS*
Dip switch settings in this guide
assume the Procal Module is held
in this position.
UP
__________ . _________ __________ . _________
example:
up, down, up, down, down...